top of page

DOUBLE-CLAD FIBER COUPLERS

The double-clad fiber couplers developed by Castor combine single-mode light transmission with multimode light transfer. Light transmission in the core is quasi-lossless from Port A to Port S, and again from Port S to Port A (see diagrams below). In the inner cladding of the double-clad fiber, light transfer occurs from the inner cladding of Port S to the multimode branch called Port B in couplers designed for light collec...

Show more

COLLECTION - LARGE INNER CLADDING

DC1060LE

SM wavelength range: 960-1260nm

SM core insertion loss: ≤0.5 dB

SM cutoff wavelength: ≤960nm

MM inner cladding transfer: ≥60%

DCF: 4/102/125 µm, 0.19/0.24NA

MMF: 200/220 µm, 0.26NA

Ideal for systems combining OCT with fluorescence imaging.

DC1300LE

SM wavelength range: 1250-1550nm*

SM core insertion loss: ≤0.5 dB

SM cutoff wavelength: ≤1250nm

MM inner cladding transfer: ≥60%

* Performances not guaranteed in water absorption region centered at 1388nm

DCF: 9/105/125 µm, 0.12/0.2NA

MMF: 200/220 µm, 0.22 NA

Ideal for systems combining OCT with fluorescence imaging.

Please reload

COLLECTION - SMALL INNER CLADDING

DC530SE

​SM wavelength range: 430-680nm

SM core insertion loss: ≤0.5 dB

SM cutoff wavelength: ≤430nm

MM inner cladding transfer: ≥70%

DCF: 2.3/15/125 µm, 0.11/0.19NA

MMF: 200/220 µm, 0.22NA

Ideal for confocal microscopy.

DC780SE

​SM wavelength range: 680-980nm

SM core insertion loss: ≤0.5 dB

SM cutoff wavelength: ≤680nm

MM inner cladding transfer: ≥70%

DCF: 4.1/26/125 µm, 0.12/0.19NA

MMF: 200/220 µm, 0.22NA

Ideal for confocal microscopy.

DC1060SE

​SM wavelength range: 970-1260nm

SM core insertion loss: ≤0.5 dB

SM cutoff wavelength: ≤970nm

MM inner cladding transfer: ≥70%

DCF: 5.3/28/125 µm, 0.14/0.2NA

MMF: 200/220 µm, 0.22NA

Ideal for confocal microscopy.

DC1300SE

​SM wavelength range: 1250-1550nm*

SM core insertion loss: ≤0.5 dB

SM cutoff wavelength: ≤1250nm

MM inner cladding transfer: ≥70%

* Performances not guaranteed in water absorption region centered at 1388nm

DCF: 8.2/43.3/125 µm, 0.14/0.2NA

MMF: 200/220 µm, 0.22NA

Ideal for confocal microscopy.

Please reload

BI-DIRECTIONAL

DC1300LQ1

​SM wavelength range: 1250-1600nm

SM core insertion loss: ≤0.5 dB

SM cutoff wavelength: ≤1250nm

MM transfer out (Port S to B): >55%

MM transfer in (Port B to S): >75%

DCF: 9/105/125 µm, 0.12/0.22NA

MMF: 105/125 µm, 0.15NA

Ideal for combining OCT and laser coagulation/therapy.

Soon available at Thorlabs.

DC1300LQ2

​SM wavelength range: 1250-1600nm

SM core insertion loss: ≤0.5 dB

SM cutoff wavelength: ≤1250nm

MM transfer out (Port S to B): >70%

MM transfer in (Port B to S): >60%

DCF: 9/105/125 µm, 0.12/0.22NA

MMF: 105/125 µm, 0.22NA

Ideal for combining OCT and diffuse spectroscopy or fluorescence imaging.

Soon available at Thorlabs.

DC1060LQ2

​SM wavelength range: 960-1260nm

SM core insertion loss: ≤0.5 dB

SM cutoff wavelength: ≤960nm

MM transfer out (Port S to B): >55%

MM transfer in (Port B to S): >75%

DCF: 4/102/125 µm, 0.19/0.24NA

MMF: 105/125 µm, 0.22NA

Ideal for combining OCT and laser coagulation/therapy.

Soon available at Thorlabs.

Please reload

bottom of page